OXYGEN, COMPRESSED
Manufacturer Information
Name
Linde, Inc
Address
10 Riverview Drive
Danbury, CT 06810-6268
Phone
8444454633
Effective Date
2022-02-03
Pictogram
NFPA
0
0
0
OX

HMIS
Health |
|
Flammability |
|
Physical Hazard |
|
Personal Protection |
|
Signal Word
Danger
Hazard Statements
- H270 - MAY CAUSE OR INTENSIFY FIRE; OXIDIZER H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED
Precautionary Statements
- P202 - Do not handle until all safety precautions have been read and understood. P220 - Keep/Store away from combustible materials, clothing. P244 - Keep reduction valves/valves and fittings free from oil and grease. P271+P403 - Use and store only outdoors or in a well-ventilated place. P370+P376 - IN CASE OF FIRE: Stop leak if safe to do so CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG20+CGA-PG10 - Use only with equipment of compatible materials of construction and rated for cylinder pressure. CGA-PG22 - Use only with equipment cleaned for oxygen service. CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG21 - Open valve slowly. CGA-PG06 - Close valve after each use and when empty. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F).
University of North Dakota Local data
- SKU # 7782-44-7
*This local data is shared by all revisions